TY - JOUR PY - 1981// TI - Biomechanical evaluation of bilateral tibial spiral fractures during skiing--a case study JO - Medicine and science in sports and exercise A1 - Zernicke, R. F. SP - 243 EP - 245 VL - 13 IS - 4 N2 - The utility of a biomechanical evaluation of an injury is shown for an incident involving bilateral tibial spiral fractures during skiing. With incorporation of directly measured binding release forces into a biomechanical model, estimates of torques transmitted to the skier's leg were determined. The analysis revealed a high potential for torsional injury to the leg with the particular release mechanism and settings used by this skier; for nearly all applications of lateral loads to the ski, this skier's bindings would not have released prior to exceeding the torsional elastic threshold of the tibia.