@article{ref1,
title="Effect of Stopangin mouth spray on blood alcohol levels measured by the Alcotest 7410 analyser made by Drager",
journal="Soudni Lekarstvi -  Czecho-Slovak Pathology and Forensic Medicine",
year="2000",
author="Zelený, M. and Mráz, J. and Pexa, T. and Mazura, I.",
volume="45",
number="4",
pages="54-56",
abstract="During a check-up of a driver by a police patrol in the Czech Republic by means of a breath analyzer of Dräger Co. an alcohol blood level of 0.50 g/kg was assessed. Later the driver reported that before the test he used at 30- and 5-minute intervals the drug Stopangin spray. In the Institute of Forensic Medicine the authors made an experiment which revealed that 22 minutes after administration of the drug the apparatus gave a negative result. Agreement with these conclusions was expressed also by a representative of Dräger Co. and the results were published as an expert opinion with a recommended procedure for the police of the Czech Republic in the South Moravian region.<p /><p>Language: cs</p>",
language="cs",
issn="0371-1854",
doi="",
url="http://dx.doi.org/"
}