@article{ref1,
title="Determination of the cooling rate for an incandescent headlight filament",
journal="Journal (Canadian Society of Forensic Science)",
year="1997",
author="Rioux, J. M. and Murphy, K. J. and Stone, H. S. and Stuart, A. W.",
volume="30",
number="2",
pages="61-64",
abstract="The rate at which a filament cools from incandescence to room temperature was determined for the respective filaments in a double beam headlight. The measurements were made in an atmosphere of 88% argon and 12% nitrogen at a reduced pressure of 600 mm mercury. From the cooling curve obtained, it was determined the filament may remain ductile for up to eight seconds after the headlight was turned off.<p />",
language="en",
issn="0008-5030",
doi="10.1080/00085030.1997.10757087",
url="http://dx.doi.org/10.1080/00085030.1997.10757087"
}