@article{ref1,
title="Dust explosion protection in linked vessels: Guidance for containment and venting",
journal="Journal of loss prevention in the process industries",
year="1999",
author="Holbrow, P. and Lunn, G.A. and Tyldesley, A.",
volume="12",
number="3",
pages="227-234",
abstract="Much industrial dust-handling plant consists of vessels connected by pipelines. If a dust explosion propagates through such a system, the overall explosion event can be more violent than if a single vessel only is involved, due to a combination of increased turbulence, pressure piling and a jet flame ignition source in the second vessel. This paper gives guidance, based on an extensive experimental programme reported previously, on two aspects of the protection of interconnected vessels: containment and venting.<p />",
language="en",
issn="0950-4230",
doi="10.1016/S0950-4230(98)00050-3",
url="http://dx.doi.org/10.1016/S0950-4230(98)00050-3"
}