@article{ref1,
title="Release from masking in virtual auditory space during sustained positive acceleration",
journal="Aviation, space, and environmental medicine",
year="2000",
author="Arrabito, G. Robert and Cheung, B. and Crabtree, R. B. and McFadden, S. M.",
volume="71",
number="5",
pages="536-542",
abstract="BACKGROUND: The use of a three-dimensional (3-D) auditory display to significantly lower subject detection level while maintaining comprehension under sustained positive G-stress was explored in this study. METHODS: Auditory threshold levels were measured for detecting a band limited pulsed signal in the presence of a broadband diotic masker at both + 1 Gz (rest position) and under sustained +3 Gz. The pulsed signal was presented diotically and was spatialized at one of four static azimuth positions on the horizontal plane. RESULTS: Results showed that auditory thresholds were not significantly affected by sustained +3 Gz stress. Compared with a diotic presentation, subjects reached an average of 6.8 dB lower auditory threshold at +1 Gz and under sustained +3 Gz when the pulsed signal was spatialized at a static position of 90 degrees azimuth on the horizontal plane. CONCLUSION: The implication of these results and suggestions for further research are discussed.<p /><p>Language: en</p>",
language="en",
issn="0095-6562",
doi="",
url="http://dx.doi.org/"
}