SAFETYLIT WEEKLY UPDATE

We compile citations and summaries of about 400 new articles every week.
RSS Feed

HELP: Tutorials | FAQ
CONTACT US: Contact info

Search Results

Journal Article

Citation

Guddat S, Fußhöller G, Beuck S, Thomas A, Geyer H, Rydevik A, Bondesson U, Hedeland M, Lagojda A, Schänzer W, Thevis M. Anal. Bioanal. Chem. 2013; 405(25): 8285-8294.

Affiliation

Institute of Biochemistry and Center for Preventive Doping Research, German Sport University, Am Sportpark Muengersdorf 6, 50933, Cologne, Germany, s.guddat@biochem.dshs-koeln.de.

Copyright

(Copyright © 2013, Holtzbrinck Springer Nature Publishing Group)

DOI

10.1007/s00216-013-7218-1

PMID

23877183

Abstract

The discovery and implementation of the long-term metabolite of metandienone, namely 17β-hydroxymethyl-17α-methyl-18-norandrost-1,4,13-trien-3-one, to doping control resulted in hundreds of positive metandienone findings worldwide and impressively demonstrated that prolonged detection periods significantly increase the effectiveness of sports drug testing. For oxandrolone and other 17-methyl steroids, analogs of this metabolite have already been described, but comprehensive characterization and pharmacokinetic data are still missing. In this report, the synthesis of the two epimeric oxandrolone metabolites-17β-hydroxymethyl-17α-methyl-18-nor-2-oxa-5α-androsta-13-en-3-one and 17α-hydroxymethyl-17β-methyl-18-nor-2-oxa-5α-androsta-13-en-3-one-using a fungus (Cunninghamella elegans) based protocol is presented. The reference material was fully characterized by liquid chromatography nuclear magnetic resonance spectroscopy and high resolution/high accuracy mass spectrometry. To ensure a specific and sensitive detection in athlete's urine, different analytical approaches were followed, such as liquid chromatography-tandem mass spectrometry (QqQ and Q-Orbitrap) and gas chromatography-tandem mass spectrometry, in order to detect and identify the new target analytes. The applied methods have demonstrated good specificity and no significant matrix interferences. Linearity (R (2) > 0.99) was tested, and precise results were obtained for the detection of the analytes (coefficient of variation <20 %). Limits of detection (S/N) for confirmatory and screening analysis were estimated at 1 and 2 ng/mL of urine, respectively. The assay was applied to oxandrolone post-administration samples to obtain data on the excretion of the different oxandrolone metabolites. The studied specimens demonstrated significantly longer detection periods (up to 18 days) for the new oxandrolone metabolites compared to commonly targeted metabolites such as epioxandrolone or 18-nor-oxandrolone, presenting a promising approach to improve the fight against doping.


Language: en